Gravis environment sensorem dolor -40 ad CXX ° F fixa Connector
Temperature / Relativum Umor Probe
Humiditas et caliditas explorata digitalis relativa specillo.Multum accurate mensuras in applicationibus ad amussim fabricandis.
LIQUIDUS et TEMPERATURA PROBATIO DE PROCESSIBUS siccandis
Series HT-Pxx vel HT-Exx digitalis humiditatis et caliditatis specillum est optimized pro duris conditionibus environmentalibus et ad temperaturae apta usque ad 120 °C (248 °F).
Directe connectit aliquam Tempe et humiditatem sensorem / humiditatem transmittentem.Uvorem probe no vim externam requiri.
Specifications, HENGKO Temp & RH Probe | |
RH Accuracy | ±2% RH ab 0 ad 100% RH |
Diu terminus summa | Typ.<0.25 %RH/yrmax <0.03 °C/yr |
Repeatability | Humilis, typ.0.21 %RHMedii, typ.0.15 %RHPrinceps, typ.0.08 %RH |
Temperatus Accuracy | ± 0.2 °C ab 0°C ad 90°C |
Corporalis | Praerupta habitationi ferro sparguntur immaculati sintered. |
Lata copia voltage range | 2.15 V ad 5.5 V |
Cable diam | φ4.5-4.8mm |
Operating Temperature | -40 ad 125°C |
Color code | Nigrum: TerraRed: 5 Vdc PowerViridis: RH output (~ I ad IV V)Flavo: Temperature (resistentia) |
Specillum Location | D38*H42.7mm |
*Continuus usus supra 120°C (248°F) in ambitus humiditatis altae (supra 90% RH) non commendatur.
Consociata
humiditas transfusor
HT-802P humiditas transmitter
HT-802W/X temp humiditas transmitter
HT-802C humiditas temperatus transmitter
HT-803 humiditas temperatus moderatoris
RS485/4-20mA
4.5-30V DC
Specillum operating temp
-40 °C ad +120°C, -40 °C ad +80°C (default)
Probe operating humiditas
0~100% RH
Operans temp of transfusor circuit
-20℃~+85℃, (10~95)% RH
Sagacitas
±4.5%RH(@20~80%RH), ±0.5℃(@25℃)
RS485/4-20mA/0-5V/0-10V
10~30V DC
Specillum operating temp
-40 °C ad +120°C, -40 °C ad +80°C (default)
Probe operating humiditas
0~100% RH
Operans temp of transfusor circuit
-40℃~+60℃, 0~99.9% RH
Sagacitas
±3.0%RH(0~90%RH, 25℃), ±0.3℃(25℃)
RS485
9 ~ 30V DC
Specillum operating temp
-40 °C ad +120°C, -40 °C ad +80°C (default)
Probe operating humiditas
0~100% RH
Operans temp of transfusor circuit
-20~ 60℃, 10 ~ 95% RH non-condensans
Sagacitas
±3.0%RH(@25℃), ±0.3℃(@-20~60℃) Officinas institutas ±0.1℃(@25℃)
Digital Output
AC 220V/12V
Specillum operating temp
-40 °C ad +120°C, -40 °C ad +80°C (default)
Probe operating humiditas
0~100% RH
Operans temp of transfusor circuit
0℃~123℃, 0~99%RH
Sagacitas
±3.0%RH, ±0.3℃
Non invenio productum quod necessitates obvium habueris?Contact nostris venditio virgam forOEM/ODM customization services!